Multi-Appliance Comfort Control
Page 28
Ducted Reverse C
y
cle
SCHEDULED MAINTENANCE
C
ONTROLS RF HANDSET ONLY
Replace the batteries in the Radio Frequency Comfort Controller (where fitted) at the start of each new
season cycle (i.e. every cooling season) with new AAA alkaline batteries.
S
YSTEM
Your BONAIRE Ducted Reverse Cycle system should be serviced annually by qualified service personnel
to ensure trouble free operation. A comprehensive maintenance and check of the system should be
carried out. Including but not limited to the following:
Refrigerant charge check
Refrigerant leak check
Compressor and fan/s operation check
Electrical wiring, connections components check including earth test
Check and test controls
Check heat exchangers for dirt buildup and clean as required
Check piping and insulation
Check unit fixings, brackets and bolts
Check fitment and fixings of all suspension, supports and access panels (especially electrical
panels)
PROBLEM SOLVING
R
ESET FUNCTION
In the unlikely event that a fault develops with the air conditioner the controller system will diagnose the
fault (where possible) and display the words RESET on the controller screen. Not all RESET displays
will adversely effect the operation of your air conditioning system.
If the controller displays RESET and the system is operating correctly it may have been an indicator that
there was abnormal operation and now all is okay. If this is the case just carry out the reset procedure
stated below.
If the controller displays RESET and the system is neither heating or cooling as required; the system has
performed a lock out procedure and must be reset before it will resume normal operation. If this is the
case perform the reset procedure stated below.
IMPORTANT NOTE
: If the system displays RESET on the controller screen repeatedly even after being
reset, contact your authorised Climate Technologies service department for instructions and possible
service needs.
RESET PROCEDURE
1. Press & release SET TIME/PROGRAM and
ENTER simultaneously to reset the unit if RESET
is displayed.
Page view 27